High Performance Sensor KF200 Series TDLAS Laser Gas Analyzer for CO O2 NH3 CO2 CH4 H2O HC HF
![qualidade [#varpname#] fábrica](http://www.portable-gasdetector.com/images/load_icon.gif)
TDLAS laser gas analyzer
,CO O2 NH3 gas analyzer
,industrial laser gas sensor


The KF200 Series Laser Gas Analyzer is developed aiming at industrial on-line analyzing and online environmental monitoring. Based on the semiconductor laser absorption spectros capy (DLAS) technology,
it is developed with features of an integrated design and high level of integration.
With various types of the KF200 series laser gas analyzer, including in-situ probing type, by-pass type,
multi-channel and disc-moulted type, etc., gases like 02, C0, NH3, CO2, CH4, H2O, HC, HF etc., can all be
analyzed. The concentration analyzing of target gases includes the macro-analysis and micro-analysis.
>>>Technical Principle
Modulate laser (tunable) wavelength by using the current and temperature to scan the specific absorption peak of the measured gas (no background gas absorption), and then get the second harmonic of the gas absorption. By using the second harmonic information and the broadening of the gas, the concentration of the gas can be calculated.
>>>Technical Specifications
Measurement Principle | Tunable Laser Absorption Spectroscopy(TDLAS) | |
Technical Data | linearity error | ≤±1%F.S. |
Span drift | ≤±1%F.S./6 months | |
Repeatability | ≤1%F.S. | |
calibration period | ≤1 time/6 month | |
Explosion-proof Grade | Exp xmd IIC T5 | |
Protection levels | IP65 | |
Response Time | Warming-up time | ≤15 min |
Response time(T90) | ≤1s | |
Interface Signals | Analog outputs | 2-wire 4-20mA signal output(Isolated, maximum load 750Ω) |
Analog inputs | 2-way 4-20mA input( temperature-pressure compensation) | |
Relay output | 3-wire relay(24V,1A) | |
Digital Communication | RS485/RS232/GPRS/Bluetooth | |
Laser Safety Standard | GB 7247.1-2001(idt IEC 60825-1:1993) | |
Operating Conditions | Storage temperature | -40ºC~80ºC |
Ambient temperature | -30ºC~60ºC | |
EMC | IEC 6100-4-2,IEC 6100-4-3,IEC 6100-4-4,IEC 6100-4-5,IEC 6100-4-11 | |
Gas jet | 0.3~0.8MPa Industrial nitrogen inlet and purification instrument gases etc. |
|
Power | DC 24V (DC 18~36V),AC 220V,power is base on specific configuration | |
Consumption | <20W | |
Installation Method | Sampling probe is mounted in the flue / pipe,system is installed nearby |
>>>Gas Detection Limit
Detection gas type | Detection limit | Detection range |
O2 | 0.01%Vol | (0-1%)Vol., (0-100)%Vol. |
CO2 | 10ppm | (0-1000)ppm, (0-100)%Vol. |
H2S | 20ppm | (0-2000)ppm, (0-100)%Vol. |
HCl | 0.1ppm | (0-50)ppm, (0-100)%Vol. |
NH3 | 0.1ppm | (0-10)ppm, (0-100)%Vol. |
C2H2 | 0.1ppm | (0-10)ppm, (0-100)%Vol. |
CO2 | 10ppm | (0-1000)ppm, (0-100)%Vol. |
H2O | 0.3ppm | (0-50)ppm, (0-100)%Vol. |
HF | 0.02ppm | (0-5)ppm, (0-10000)ppm |
HCN | 0.3ppm | (0-30)ppm, (0-1)%Vol. |
CH4 | 0.4ppm | (0-40)ppm, (0-100)%Vol. |
C2H4 | 0.6ppm | (0-60)ppm, (0-100)%Vol. |
Remark2: By increasing the optical path, proportionally lower detection limit.
>>>Company Information:
♦ Nanjing Kelisaike Safety Equipment Co., Ltd. founded in 2004, Nanjing Kelisaike has three subsidiaries
in Beijing, Xi'an and Xinjiang province, and over 30 domestic sales service centers.
♦ Standard products include the K60 series portable single gas detectors, K60-IV series multi gas
detectors, K800 series fixed gas transmitters, K500 series wall-mounted gas detectors, K1000 series
gas detector control panel units, KL99 series air breathing apparatuses, etc.
♦ Nanjing Kelisaike is also a factory with rich experience in OEM service,providing professional design
and manufacturing of customized products.
>>>Product Catalogue:
>>>Package and Delivery:
>>>Our Exhibition:
>>> Our Services
1.For all our customers, our products have 1 year warranty, and life-long maintenance.
2.All inquiries will be replied in 24 hours.
3.Providing technical support, professional engineers are specialized in dealing with gas monitoring problems you met.
4. OEM and ODM service are welcome.
5.KELISAIKE plant is located in Nanjing, only 1 hour by high speedtrain from Shanghai. Welcome to visit the factory.
6.All products are well tested and packed before shipment; the certificate of inspection will be provided.
>>>Why choose KELISAIKE:
1. Mutual benefit : We are a factory. The price is much more competitive than others in the same quality.
2. Professional engineers: With 10+ years history, KELISAIKE has a professional engineering team: 4 engineers who have more
than 10 years' experience and over 5 engineer assistants in gas detection line, with Hi-Tech manufacturing equipments, we make more accurate and stable products.
3. Customize : We have strong R&D team, the custom product as your request are available.
4. Free OEM service : (a) Silk-printing your Logo(≥100PCS). (b) Design your color box(≥500PCS).
5. Mix order : We accept mix order, different model and small quantity order.
6. After service: (a) 1 Year warranty. (b) If there's any inferior-quality products are found, new ones could be sent to replace at free cost in the next order after confirmation.
![qualidade [#varpname#] fábrica](http://www.portable-gasdetector.com/images/load_icon.gif)
Incineração de resíduos CEMS Sistema de monitorização contínua das emissões de gases de combustão HCl CO
![qualidade [#varpname#] fábrica](http://www.portable-gasdetector.com/images/load_icon.gif)
KF200 Analisador de Gás Laser In-situ TDLAS para Monitoramento em Tempo Real de CO, NH₃, HCl e O₂ em Emissões Industriais
Imagem | parte # | Descrição | |
---|---|---|---|
![]() |
Incineração de resíduos CEMS Sistema de monitorização contínua das emissões de gases de combustão HCl CO |
Continuous Emission Monitoring System for HCl and CO in Waste Incineration Flue Gas (CEMS)
|
|
![]() |
KF200 Analisador de Gás Laser In-situ TDLAS para Monitoramento em Tempo Real de CO, NH₃, HCl e O₂ em Emissões Industriais |
The KF200 Series Laser Gas Analyzer is specifically designed for industrial online analysis and continuous environmental
|